Section 3 • Scheduled Maintenance Procedures
Part No. 96316
GS-30 • GS-32 • GS-46
3 - 33
September 2005
REV B
CHECKLIST
E
PROCEDURE
10 Install the hydraulic pump inlet hard line into the
tank. Install the fitting onto the pump and torque
to specification. Refer to Section 2,
Specifications.
11 Install the hydraulic pump return hard line into
the tank. Install the fitting onto the hydraulic
filter head and torque to specification. Refer to
Section 2,
Specifications.
12 Fill the tank with hydraulic oil until the fluid is at
the
FULL
indicator on the hydraulic tank. Do not
overfill.
13 Activate the pump to fill the hydraulic system
with oil and bleed the system of air.
Component damage hazard. The
pump can be damaged if operated
without oil. Be careful not to empty
the hydraulic tank while in the
process of filling the hydraulic
system. Do not allow the pump to
cavitate.
14 Repeat steps 12 through 13 until the hydraulic
system and tank are both full.