1.2 Technical specifications
Omni
DEL e
5
ã
Terberg Machines B.V. IJsselstein, The Netherlands
All rights reserved. No part of this book may be reproduced, stored in database or retrieval system, or published, in any form or in any way,
electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from the publisher.
2-wheel bins
4-wheel containers
flat lid
4-wheel containers
roll top
Paladin
containers
Capacity
80 - 360 litres
500 - 1280 litres
770 and 1100 litres
900 litres
According to standard
EN 840-1
EN 840-2
EN 840-3
--
Lifting capacity
1600N (160 kg)
5000N (500 kg)
Cycle time (excl. dwell time)
6.0 seconds
11 seconds
Time in tipping position
Adjustable
Adjustable
Guidelines and standards
2006/42/EG, EN 1501-1 & EN 1501-5:2011
Weight
595 kg (depending on configuration)
Noise levels
≤ 65 dB(A)
Vibrations
≤ 2.5 m/s
2
Operating voltage
24 Volts
Maximum current consumed by control
10 Amps
Oil flow
40-60 litres/minute
Working pressure PTO
Min. 180 bar / Max. 250 bar
Return pressure
Max. 2.0 bar
Quick release couplings
DIN 25, ISO 72141-1
2-wheel bins
4-wheel containers
flat lid
Capacity
80 - 360 litres
500, 660 and 770 litres
According to standard
EN 840-1
EN 840-2
Lifting capacity
1000N (100 kg)
3500N (350 kg)
Cycle time (excl. dwell time)
6.0 seconds
11 seconds
Time in tipping position
Adjustable
Adjustable
Guidelines and standards
2006/42/EG, EN 1501-1 & EN 1501-5:2011
Weight
655 kg (depending on configuration)
Noise levels
≤ 58 dB(A)
Vibrations
≤ 2.5 m/s
2
Operating voltage
24 Volts
Maximum current consumed by control
10 Amps
Average power consumption during normal daily use
20 Ah
Average electrical power 2-wheel bin
1.8 kW
Maximum electrical power 2-wheel bins (1000N)
3.6 kW
Maximum electrical power 4-wheel containers (5000N)
5.2 kW
Omni
DEL
Bins/containers to be emptied,
“teardrop” catcherbar
Bins/containers to be emptied,
2-position catcherbar / lid opener
The emptying of bin/container types other than
those indicated above, is not permitted with
this bin lift system. If in doubt, please contact
your distributor.