4.8 Electrical connection to compactor body: Omni
DEL and OmniDEL e
The connection between the bin lift and the body of the refuse collection vehicle is in accordance with
standard EN 1501-5.
Check the following points before making the connection:
- Start the vehicle and switch on the compactor.
- Press the compactor system start button.
The compactor must now operate as a “hold to run” system; as soon as the start button of the
compactor installation is released the compactor must stop.
- Check that the emergency stop switches of the compactor installation are working properly and that the
emergency stop buzzer in the cabin also works.
- Reset the emergency stop switches and check again that the compactor works as a “hold to run” system.
- Separate the 16-pole plug from the 16-pole fixed socket.
- Connect the body plug into the fixed socket on the bin lift.
- Connect the bin lift plug to the fixed socket on the body.
Electrical plugs and socket boxes
Make sure that the work area of the compac-
tion mechanism is sufficiently protected.
The following work may only be carried out by
qualified personnel.