16-pole plug fixed socket pin / wire definitions on bin lift
8
16
7
15
6
14
5
13
4
12
3
11
2
10
1
9
Pin number: Signal type: Signal description:
Observation:
1
Input
RCV in neutral gear = +24 V
16 to 34 V
2
Not connected
Info no bin lift fitted
3
Output
Safe distance from footboard level
4
Output
Safe distance from footboard level
5
Input
Footboards OCCUPIED 0V
6
Output
Clash between bin lift and packer plate
(info to RCV that container is within
reach of packer plate).
+24 V = packer plate stops, as soon as
the container is out of reach of the
packer plate an extra start signal
compaction cycle is given.
7
Bus
CleAN open CAN (L)
8
Not connected
9
Not connected
10
Not connected
11
Not connected
12
Input
Emergency stop control system:
normal “safe” state = +24 V
Maximum 3 Amps
13
Output
Signal hopper plate switch (OK = +24 V).
Safety distance okay from ground level.
14
Input
Clash between packer plate and bin lift
(info to bin lift that packer plate is within
reach of container).
+24 V = bin lift stops in horizontal
position out of reach of the packer plate.
15
Bus
CleAN open CAN (H)
16
Output
Signal hopper plate switch (OK = +24 V).
Safety distance okay from ground level.
16-pole socket box contact side