18
ã
Terberg Machines B.V. IJsselstein, The Netherlands
All rights reserved. No part of this book may be reproduced, stored in database or retrieval system, or published, in any form or in any way,
electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from the publisher.
4.8.1 Explanation of cable loom connection pins
16-pole plug cable loom pin / wire definitions from bin lift
* CleAN open is a CAN data protocol for refuse collection vehicles; it makes data communication possible between the
various components (bin lift, identification system, weighing system and suchlike) of the refuse collection vehicle.
16-pole plug contact side
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
Pin number: Signal type: Signal description:
Observation:
1
Supply
Power supply in
+24 V, direct from chassis,
5 Amps maximum
2
Supply
Power supply in
+24 V, direct from chassis,
5 Amps maximum (linked with pin 1)
3
Gnd
Ground
Mass chassis, 3 Amps maximum
4
Gnd
Ground
Mass chassis, 3 Amps maximum
(linked with pin 3)
5
Input
Reverse gear e24 V
6
Output
Chairs low position,
out of travel po24 V
7
Bus
CleAN open* CAN (L)
8
Input
Emergency stop circuit 1
Loop 1, input from the RCV,
maximum 300 mAmps and 50 V
9
Output
Emergency stop circuit 1
Loop 1, output to RCV,
maximum 300 mAmps and 50 V
10
Input
Emergency stop circuit 2
Loop 2, input from RCV,
maximum 300 mAmps and 50 V
11
Output
Emergency stop circuit 2
Loop 2, output to RCV,
maximum 300 mAmps and 50 V
12
Output
Bin count pulse (one pulse per bin,
no matter if 2- or 4-wheeled)
+24 V, 300ms
1 sec. maximum
13
Input
“RCV” ready
Body is in working order, lifter can use
revs and oil.
14
Output
Hydraulic supply request and
engine speed request (+24 V)
15
Bus
CleAN open CAN (H)
16
Output
Start compaction cycle
+24 V, 300ms
1 sec. maximum