OPERATION MENU’S
6.4.7
Assigns Control Zones to Paddle Inputs
Figure 6-33 Assign Control Zones To Paddle Inputs
The Digital Temperature Controller (DTC) can use different thermocouples as input signals.
Default the spike TC’s are used to control the temperature as they give the fastest response
and shortest recovery timer. If even more accurate temperature are required or the
(automatic) profiling recipes is to be performed the paddle TC’s can be assigned to be used as
input signals to the DTC the “Assign Control Zones to Paddle Inputs” menu allows the
temperature control zones to be connected to the paddle thermocouple.
NOTE
Temperature Control Zone 1 is at the load side, zone 3 (or 5) is at the
source side.
Assign the control zones first and then connect the paddle TC wires
one at a time, checking the correct thermocouple to be connected.
T
OUCHSCREEN
R
EFERENCE MANUAL
6-34