OPERATION MENU’S
6.2.2.2
Normal Temperature Table
Figure 6-19 Normal Temperature Table
The Normal Temperature Table consists of 16 positions (0-15) for process temperature
recipes. These process temperature recipes can be selected based on recipe number. Every
process temperature recipe contains the following parameters:
Recipe number:
The recipe number is the main source of recipe selection. To select a recipe, position the
cursor over the recipe number and enter the number of the new recipe in the range 0 to 15 or
press <RC+> or <RC-> to scroll up and down. When the desired recipe number has been
selected press <RETURN> to fill in its parameters.
Temperature Setpoint:
Enter the Temperature Setpoint for each zone. Each entry must be in the range 0.0 (Tmin.)
to 1400.0 (Tmax.)
0
C, as defined in the DTC configuration based on the type of
thermocouple, see Figure 6-19.
Slope:
Te slope is the temperature rise in
C/min of the Setpoint. The actual temperature will rise
with equal rate after some delay. Each entry can be in the range 0,0 to 99.0
C/min. the actual
temperature rise is hardware restricted (due to power transformer limitation) and is software
limited (see DTC configuration in Figure 6-18) to extent the heating element lifetime.
T
OUCHSCREEN
R
EFERENCE MANUAL
6-18