FSP200
29
Tempo Communications Inc.
1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Section 4.
Specifications
Applicable Fibers
SM (G.652); MM (G.651); DS (G.653); NZDS (G.655); BIF (G.657); EDF
Fiber Cleaved Length
10mm
Cladding Diameter
80-150μm
Coating Diameter
100-1000μm
Fiber Count
Single
Fiber Aligning Method
Core alignment
Splice Loss (Typical)
0.02 dB (SM); 0.01 dB (MM); 0.04 dB (DS); 0.04 dB (NZDS & BIF)
Splicing Mode
60 Preset / User Definable Modes
Splice Time (Typical)
7s (1)
Boot Time
5 seconds
Number of Splices Per Battery Charge
200 (2)
Splice-On-Connector
SC, LC, FC, ST
Arc Calibration Mode
Automatic and Manual
Protection Sleeve Length
60mm, 40mm, Micro Sleeves
Ingress Protection (3)
IP5X (Dust); IPX2 (Water)
Storage of Splice Results
5,000 Results, 100 screenshots
Drop Test
76cm on five axis
Tension Test
2N
Fiber Display Magnification
200X
Tube Heating Mode
20 Preset / User Definable Modes Adjustable 0-240 seconds
Tube Heating Time (Typical)
18s (4)
Attenuator Mode
0.1 to 15 dB
Electrode Life
5000 Splices
Display
3.5” Color, Turn-Over LCD
Connectivity
USB
Operating Conditions
Pressure: 0 to 16,404 feet
(0 to 5,000 meters) above Sea Level
Humidity: 0 to 95%
Temperature: -4 to +131F (-20 to +55C)
Storage Conditions
Temperature: -40 to +158°F (-40 to +70°C)
Power Supply
100 to 240V AC Adapter; Li-ion Battery (4400 mAh)
Weight
3.74lbs (1.7kg) with battery
Dimensions (HxWxT)
4.9” x 4.9” x 5.3” (125 x 125 x 135mm)
Vibration Resistance
10Hz – 500Hz with a spectral density of 0.03g2/Hz
Password Protection
Yes
(1) Fast mode. (2) 90s/cycle splice time and power save functions activated. Number of cycles may vary depending on battery status and ambient operating conditions. (3) Dust resistance and rain
resistance test do not guaran-tee that the product will not be damaged under these conditions. (4) Dependent on splice protector used and ambient conditions. Time quoted is with power mode enabled and assuming that the oven is not cold.
*Specifications subject to change without notice.