Summary of electrode activation
A
B
F
G
C
D
I
J
E
H
A:
Cleaning Arc
B:
Prefuse Time
C:
Arc1 Time
D:
Arc2 Time
E:
Rearc Time
F:
Prefuse Power
G:
Arc1 Power
H:
Arc2 Power
I:
Arc2 ON Time
J:
Arc2 OFF Time
Note: Not all settings are available in the AUTO modes.
This is a general guideline for the user to control the fusion settings. Every type of fiber has its own characteristics and
properties that may require the manual setting of these parameters. The user will have to perform careful experiments with their
individual fibers to obtain optimum results.
Heater Mode Menu
(H–Mode)
There are 20 user-programmable heating modes. Select the one most suitable for the protection sleeve used.
Each tube-heating mode is optimized for a type of protection sleeve. These modes can be found in the database area for
reference. The operator can copy the one an dpaste it into the user-programmable area for customized protection sleeves.
(1) Select Heater Mode
Select “H–Mode” to access the available heater modes. Use the arrow keys to highlight the desired heater mode. Then press OK
to confirm.
Select the heater mode most suitable for the protection sleeve to be used.