WE310F5-X IP2WiFi Legacy AT Command Reference Guide
80664ST11079A Rev. 3
Page 18 of 79
2021-10-25
Not Subject to NDA
5.
HOST INTERACTION
Interface
The embedded host uses one of the interfaces (UART/SPI/SDIO) to connect to the Serial-
to-WiFi Application.
5.1.1.
Hardware Flow Control
Command Description
This command is used to enable/disable hardware flow control for the UART interface.
Command Syntax
AT&Rn
Parameter Description
Table 8: Hardware Flow Control Parameters.
Parameter
Optional/Mandatory
Value
Description
n
Mandatory
0 (default)
Hardware flow control is
disabled.
1
Hardware flow control is
enabled.
Synchronous Response
Table 9: Hardware Flow Control Synchronous Response.
Responses
Remarks
OK
Success
ERROR:INVALID INPUT
If parameter is not valid. (other than 0 or 1)
Note/Tip: Software Flow Control is not supported in WE310F5-X
module.
5.1.2.
Interface Verification
Command Description
The command AT can be issued to verify that the interface is operating correctly or not.
Command Syntax
AT