Front Panel Option Selection
4-40
FT 100S
PUSHBUTTON ACTION:
YES-
Selects the first DS0 channel number
ff
and advances to the
transmit clock source display
NO-
Increments the starting DS0 number
ff
and displays the
ending DS0 number
ll
HOME-
Returns to Port Number Selection
Transmit Clock Source
This display selects the DTE transmit clock source:
Internal
The unit uses the transmit clock output to clock DTE
transmit data into the transmit buffer. Where the DTE is
located near the unit, internal clock is usually selected.
External
The unit uses the external transmit clock from the DTE to
clock DTE data. In applications with a high bit rate and a
long DTE cable, it may be necessary to use the external
clock option.
In external clock operation, the transmit clock output from the unit is
routed to the DTE and sent back to the unit along with the data line. This
eliminates any phase misalignment between the clock and data signal
due to cable phase delay and insures a proper signal / clock relationship
at the unit input.
PUSHBUTTON ACTION:
YES-
Selects the displayed option and advances to transmit clock
polarity display
NO-
Toggles between INTERNAL and EXTERNAL options
HOME-
Returns to Port Number Selection
DTE Port
<type>
Tx CLK =
<source>
Summary of Contents for FT100 S
Page 10: ...ESF Framing C 4 Framing Format Conversion C 6 Performance Monitoring C 6 Service and Support...
Page 22: ...Installation 2 8 FT 100S...
Page 28: ...Hardware Configuration 3 6 FT100S...
Page 106: ...Control Port Operation 6 28 FT 100S...
Page 108: ...Maintenance 7 2 FT 100S...
Page 116: ...Specifications A 4 FT 100S...
Page 120: ...Control Port Command Quick Reference B 4 FT 100S...
Page 128: ...T1 Overview C 8 FT 100S...