Front Panel Option Selection
FT
100S
4-25
PUSHBUTTON ACTION:
YES-
No action
NO-
Advances to RESTART TEST?
HOME-
Returns to the top of the present test menu
Restart Test Display
The user can reset the bit error count, average BER, and elapsed seconds
for the test pattern tests if desired.
PUSHBUTTON ACTION:
YES-
Restarts the error counters and returns to the BIT ERRORS
display
NO/
HOME-
Returns to the top of the present test menu
SELF TEST
Even though there is no singular self test command or function, there is
self test capability in the FT 100S.
To execute a self test, first enter the T1 LOCAL LOOPBACK MODE
previously described in this chapter. Next, with the T1 Local Loopback
still active, enter the DTE TEST PATTERN MODE previously
described in this chapter. Using the LCD, it is possible to determine if
the unit is operating error free. Figure 4-8 shows the FT 100S in self test.
To terminate the FT 100S self test, the user must terminate the DTE
TEST PATTERN MODE and the T1 LOCAL LOOPBACK MODE as
described previously in this chapter.
DTE Test Pat
Restart Test?
Summary of Contents for FT100 S
Page 10: ...ESF Framing C 4 Framing Format Conversion C 6 Performance Monitoring C 6 Service and Support...
Page 22: ...Installation 2 8 FT 100S...
Page 28: ...Hardware Configuration 3 6 FT100S...
Page 106: ...Control Port Operation 6 28 FT 100S...
Page 108: ...Maintenance 7 2 FT 100S...
Page 116: ...Specifications A 4 FT 100S...
Page 120: ...Control Port Command Quick Reference B 4 FT 100S...
Page 128: ...T1 Overview C 8 FT 100S...