Front Panel Option Selection
4-32
FT 100S
PUSHBUTTON ACTION:
YES-
Advance to T1 framing option display: T1 FRAMING = SF
(ESF) CHANGE IT?
NO- Advances
to
DTE
PORT
OPTIONS?
submenu
HOME-
Returns to CONFIGURATION OPTIONS? menu
T1 Framing
The T1 network signal framing mode can be set to either Superframe
(SF or D4) or Extended Superframe (ESF) mode.
PUSHBUTTON ACTION:
YES- Toggles
between
ESF
and
SF(D4)
NO- Saves
option
selected
HOME-
Returns to T1 LINE OPTIONS? submenu
Line Code
Select one of two options for the network T1 line code:
AMI Alternate
mark
inversion
B8ZS
Binary 8-zero substitution: With B8ZS, a bipolar violation
sequence replaces strings of 8 zeros in the transmit data and
insures a minimum ones density to the network.
PUSHBUTTON ACTION:
YES- Toggles
between
AMI
and
B8ZS
NO-
Saves option selected and advances to PRM option
HOME-
Returns to T1 LINE OPTIONS? submenu
T1 Framing = ESF
Change It?
T1 Framing = ESF
Change It?
Summary of Contents for FT100 S
Page 10: ...ESF Framing C 4 Framing Format Conversion C 6 Performance Monitoring C 6 Service and Support...
Page 22: ...Installation 2 8 FT 100S...
Page 28: ...Hardware Configuration 3 6 FT100S...
Page 106: ...Control Port Operation 6 28 FT 100S...
Page 108: ...Maintenance 7 2 FT 100S...
Page 116: ...Specifications A 4 FT 100S...
Page 120: ...Control Port Command Quick Reference B 4 FT 100S...
Page 128: ...T1 Overview C 8 FT 100S...