![Telenetics Corporation FT100 S Installation And Operation Manual Download Page 57](http://html1.mh-extra.com/html/telenetics-corporation/ft100-s/ft100-s_installation-and-operation-manual_1082085057.webp)
Front Panel Option Selection
FT
100S
4-29
Timed Error Data
Performance history is accumulated and stored in intervals of 15
minutes each for a maximum of 24 hours (96 intervals).
These menus access displays recording error totals within
•
the last 24 hours
•
the current 15 minute interval
•
or any 15 minute interval during the past 24 hour period.
The following error count displays may be accessed:
The first column distinguishes the time option “menu” for that data.
(The first column of each of the Current Interval displays includes the
current interval second, 1 to 900.)
The second column records the total error count nnn per the specific
type of error data:
ES
Errored seconds
BES
Bursty errored seconds
SES
Severely error seconds
24 Hour Totals
15 min Interval
Data?
Interval ES
#
nnn
Interval BES
#
nnn
Interval SES
#
nnn
Interval UAS
#
nnn
Interval LOFC
#
nnn
Interval LCVS
#
nnn