Operation Model
2120XL
Teledyne Analytical Instruments
40
Dig Filt:
The Model 2120XL includes a user adjustable
digital filter. The filter has settings 1-10. Setting 1 is the least
amount of filtering and 10 is the highest level of damping.
Self–Test
:
The instrument performs a self-diagnostic test to
check the integrity of the power supply, output boards and
amplifiers.
PSWD:
Security can be established by choosing a 5 digit
password (PSWD) from the standard ASCII character set.
(See Installing or Changing a Password, below, for a table of
ASCII characters available.)
Logout:
Logging out prevents an unauthorized tampering
with analyzer settings.
More
:
Select and enter
More
to get a new screen with
additional sub functions listed.
Auto-Cal
:
Used to define an automatic calibration sequence
and/or start an Auto-Cal.
Flow:
Used to set the flow through the flow controller.
TRAK/HLD
:
The operator sets whether the instrument
analog outputs track the concentration change during
calibration and sets a time delay for the concentration alarms
after calibration
Cal Hold Timer:
Allows alarm suppression and analog
output value hold times during calibration events for a user
adjustable period.
Model
:
Displays Manufacturer, Model, and Software
Version of the instrument.
Out-Cal:
Analog output calibration allows the user to
calibrate the 4 and 20 mA analog output values.
Lin:
Used to linearize the output of the controller.
To enter any of the system functions, use the
◄►
arrow keys to
move to the function and then use the ENTER key to engage that
function.
4.5.1.1
D
IGITAL
F
ILTER
Upon entering the digital filter function, the following screen
appears on the display:
Summary of Contents for 2120XL
Page 12: ...Model 2120XL Teledyne Analytical Instruments xii ...
Page 28: ...Operational Theory Model 2120XL Teledyne Analytical Instruments 16 ...
Page 46: ...Installation Model 2120XL Teledyne Analytical Instruments 34 ...
Page 76: ...Operation Model 2120XL Teledyne Analytical Instruments 64 ...
Page 82: ...Maintenance Model 2120XL Teledyne Analytical Instruments 70 ...