Installation instructions
│
T24
│
Annex A: List of errors and error messages
Event code
Event description
Category
StopButtonAdcInvalidValue (1162)
[ The AD converter used to
measure the stop button state
measured an invalid value ]
2hw
StopButtonInconsistentBranchesDetectedByCpu2
(1163)
[ According to CPU2 the two
branches of the stop button
does not agree about the
state of the stop button ]
2hw
SafetyErrorRs485Cpu2CannotOverrideDe
(1164)
[ CPU2 could not override
CPU1 RS485 driver enable. RX
was low xxxx times when doing
break from CPU1 (majority
should be high, see code) ]
2hw
SafetyErrorRfActiveWhenProhibited (1165)
[ The RF (cc2520) clock was
activated by CPU1 when it was
not allowed to ]
1
SafetyErrorCPU1VsCPU2SafeDataInconsisteny
(1166)
[ CPU1 and CPU2 does not
agree on the state of the
safe data ]
1
SafetyErrorRfPowerActiveWhenNotAllowed
(1168)
[ The RF power is on while it
shall not be ]
1
SafetyErrorCpu1DetectedSeqNrOutOfSync
(1169)
[ The sequence number sent
from CPU2 to CPU1 was
considered out of sync by
CPU1 ]
1
SafetyErrorCpu2DetectedSeqNrOutOfSync
(1170)
[ The sequence number sent
from CPU1 to CPU2 was
considered out of sync by
CPU2 ]
1
SafetyCrcErrorInSettingsBlock (1171)
[ Settings block id xxxx had
safetyCRC xxxxxx, expected
xxxxxx ]
2sm
StopButtonInconsistentBranchesDetectedByCpu1
(1172)
[ According to CPU1 the local
ES2 branch and the ES1 branch
from CPU2 are inconsistent ]
2hw
84