![Tektronix TekRanger 2 TFS3031 Service Manual Download Page 50](http://html1.mh-extra.com/html/tektronix/tekranger-2-tfs3031/tekranger-2-tfs3031_service-manual_1078196050.webp)
Specifications – TekRanger (serial nos. below B052000)
TFS3031 TekRanger/TekRanger 2 Service Manual
1–27
Table 1–22: Vertical System Measurements (Standard 1310 nm Singlemode, Options 04 and 06)
Characteristic
Performance Requirement
Supplemental Information
Linearity
3Ćminute average.
±0.02 dB/dB typical
From 9 dB above RMS floor to 1.5
dB below maximum signal level.
Measurement Accuracy
TwoĆPoint
Splice Loss
LSA Fiber Loss
Reflectance
3 minute average,
±
0.1 dB/dB for
events 10 dB above 98% noise
floor, 95% confidence
±
4 dB maximum error below -40
dB. 10 m to 1 m pulsewidth.
Reflections may clip above -40
dB.
Table 1–23: Measurement Range (Standard 1310 nm Singlemode, Options 04 and 06)
Characteristic
Performance Requirement
Supplemental Information
Loss Threshold (dB)
Max PW
0.05
500 m
0.2
2000 m
0.5
2000 m
1.0
2000 m
Measurement Range (dB)
Minimum
Typical
10
13
18
20
20
22
21
23
IntelliTrace mode averaging and
analysis less than 3 minutes.
For isolated nonreflective event or
grouped NRĆreflective events.
Reflective event return loss >-40
dB; distance >4 km past NR event.
(This means that a small,
nonreflective event followed closely
by a small, reflective event will
reduce the repeatability of finding
these two events).
Table 1–24: Single-Event Distance Measurement Repeatability
1
(Standard 1310 nm Singlemode, Options 04 and 06)
Characteristic
Performance Requirement
Supplemental
Information
Range from Front Panel
(dB)
0 to 1.5
1.5 to (DR
4
ć8)
(DRć8) to DR
Reflective
2
2.5 m
20 m
40 m
Nonreflective
3
2.5 m
20 m
160 m
IntelliTrace mode
1
Multiply by 0.001% of range for timebase error. These data are for a 0.5 dB event with 95% probability on a single unit.
2
Reflectance greater than -45 dB, 0.5 dB loss.
3
Reflectance less than -60 dB, 0.5 dB loss.
4
DR is the dynamic range for 2000Ćm pulse width from table 1-25. DR is the 98% dynamic range, defined as dynamic range SNR=1 minus 1.5.
Summary of Contents for TekRanger 2 TFS3031
Page 5: ......
Page 27: ...Module Level Service 1 4 TFS3031 TekRanger TekRanger 2 Service Manual...
Page 39: ...Battery Recharging and Replacement 1 16 TFS3031 TekRanger TekRanger 2 Service Manual...
Page 129: ...Accessories and Options 1 106 TFS3031 TekRanger TekRanger 2 Service Manual...
Page 133: ...Theory of Operation 2 4 TFS3031 TekRanger TekRanger 2 Service Manual...
Page 265: ...Replaceable Parts 6 14 TFS3031 TekRanger TekRanger 2 Service Manual...
Page 270: ......
Page 271: ......