Introduction to Oscilloscopes and Probes
TDS1000B and TDS2000B Series Oscilloscopes – Operator Training Kit
1-25
Passive Voltage Probes
Passive voltage probes
consist of wires, connectors,
resistors, and capacitors. Passive voltage probes typically
have attenuation factors of 1X, 10X, and 100X for different
voltage ranges. Attenuation factor represents the number of
times a probe attenuates a signal. In case of applications
where signal amplitudes require the best vertical sensitivity
of an oscilloscope, a 1X probe can be used. You can use a
switchable 1X/10X probe for a mix of low amplitude signals
(10 mV) and moderate to high amplitude signals (10 V or
more).
A switchable 1X/10X passive voltage probe provides
the characteristics of both 1X and 10X probes. 1X and
10X passive voltage probe modes have different
characteristics regarding attenuation factors, bandwidth,
rise time, and impedance. For example, as compared to
a 10X passive voltage probe, a 1X passive voltage
probe will present a much higher capacitive load to the
circuit being tested.