Manuale d’istruzione per l’installazione, la manutenzione e l’uso
Brasiere a gas ribaltabili BS80.G7 / BS8.G7
05.11.02
pagina
50
Table 3
– Technical data (injector table)
Cat.: II2H3+
TYPE OF CONSTRUCTION “A”
Model
BS80.G7 / BS8.G7
Rated power (kW)
12
Minimum power (kW)
“ON/OFF”
Gas consumption
G20 (Hi = 9,45 kWh/m3) in m3/h
G30 (Hi = 12,68 kWh/kg) in kg/h
1,27
0,95
Injectors
D.
In
1/100
mm
Pilot
G20 20mbar: Rated power
Minimum power
40
4X135
“ON/OFF”
20
4X85
“ON/OFF”
Pilot
G30 28-30/37 mbar: Rated power
Minimum power
Primary distance “H” G20
G30
20
20
Table 6
– Gas inlet pressure
Table 6a
Nominal main pressure
for the
different types of gas
Gas family 2
– Natural
20 mbar
Gas family 3
–LPG
28-30/37 mbar
Table 6b
Operation permissible
if pressure is in
the range:
Gas family 2
– Natural
da 17 a 25 mbar
Gas family 3
–LPG
da 20/25 a 35/45 mbar
Table 6c
Operation non permissible
if
pressure is
lower
than:
Gas family 2
– Natural
17 mbar
Gas family 3
–LPG
20/25 mbar
Table 6d
Operation non permissible
if
pressure is
higher
than:
Gas family 2
– Natural
25 mbar
Gas family 3
–LPG
35/45mbar