S.p.A.
ITEM TE550
Instruction manual
By means of the keys and , it is possible to check the other cycles of the analysed
welding.
PRG 001 SPOT 12340
WELD TIME 02 ~
POS+ 43.26 kA 142°
NEG- 43.26 kA 142°
PRG 001 SPOT 12340
WELD TIME 10 ~
POS+ 43.26 kA 142°
NEG- 43.26 kA 142°
By further pressing the key , it is possible to check the
stepper function
status.
SPOT MAX 12340
SPOTS 00000
INCREMENT 00% OF 00%
STEP NUM. 00 OF 00
SPOT MAX 12340
It indicates the maximum spots number programmed in the stepper function.
SPOTS 00000
It indicates the number of the already welded spots.
INCREMENT 00% OF 00%
It indicates both the carried out stepper value and the value to be reached, both expressed in
percentage.
STEP NUM. 00 OF 00
It indicates the carried out segment spot and the spot to be reached.
By pressing the key again, it is possible to carry a further welding analysis out in ENERGY
working mode.
This frame may be displayed by means of the supplementary expansion board item 50200
only.
PRG 001 SPOT 12340
CYC 01 ENERGY 00000J
V+ 00.00 E+ 00000J
V- 00.00 E+ 00000J
PRG 001
It indicates the program number used for the last weld sequence.
SPOT 12340
It indicates the welded spot number being analysed. It always stands for the last carried out
welding.
CYC
It indicates the cycle of the whole welding time relevant to the welding being analysed.
ENERGY
It indicates the total energy value of the welding being analysed.
V+ 00.00 E+00000J
It indicates the voltage value, expressed in volts, of the welding cycle positive half-period and
the relevant energy value, expressed in joule, of the cycle taken into consideration.
V- 00.00 E+00000J
It indicates the voltage value, expressed in volts, of the welding cycle negative half-period and
the relevant energy value, expressed in joule, of the cycle taken into consideration.
11/92