Instruction manual
ITEM TE550
S.p.A.
22/92
QUALITY - T*
IDENT
IDENT. MIN
0.000 – 6.000 mm
IDENT. MAX
0.000 – 6.000 mm
QUALITY - T*
TH+ID
THICK. MIN
00.00 – 60.00 mm
THICK. MAX
00.00 – 60.00 mm
IDENT. MIN
0.000 – 6.000 mm
IDENT. MAX
0.000 – 6.000 mm
QUALITY - T*
ZERO
INPUT VE/PRE (FEATURES MENU)
PRE
PRES. MIN
0.00 - 10.0 bar
PRES. MAX
0.00 - 10.0 bar
Existing particular conditions:
If the OFF TIME is set to 0, the control unit will work in single cycle.
By setting the PRE-WELD parameter to zero, the pre-welding process will not be carried
out.
By setting the POST-WELD parameter to zero, the post-welding process will not be carried
out.
By setting the same value for both CURR. MIN and CURR MAX, the limits of current are
disabled.
By setting the same value for both ANGLE MIN and ANGLE MAX, the limits of the
conduction angles are disabled.
By setting the same value for both THICK. MIN and THICK. MAX, the limits are disabled.
By setting the same value for both IDENT. MIN and IDENT. MAX, the limits are disabled.
By setting the same value for both PRES. MIN and PRES. MAX, a programming error is
generated.