S.p.A.
ITEM TE550
Instruction manual
PRESSURE 02.3 bar
Indicates the value of the pressure measurement realized by the external sensor just after the
squeeze phase. This value is updated in WELD and NO WELD.
PRESS. MIN 01.5 bar
Indicates the value of the minimum pressure limit set when programming. This value is
updated in WELD and NO WELD.
PRESS. MAX 02.5 bar
Indicates the value of the maximum pressure limit set when programming. This value is
updated in WELD and NO WELD.
By pressing the key again, it is possible to check
the displayed errors list
.
ERRLOG 01 SPOT 00000
ERR 0101
NO EMERGENCY ERROR
OR RELAY RESTART ERR
ERRLOG 01
It indicates which error it is being displayed in chronological order. The last chronologically
displayed error is expressed through number 01: the other errors are then stored through an
increasing number. A maximum of 20 errors can be stored; by exceeding this quantity, the
oldest errors are cancelled to be replaced with the most recent ones.
SPOT 00011
It indicates which welding spot the error is experienced at. The number is relevant to the
counted welded spots, therefore it may happen that the spots number of several consequent
errors is not shown in increasing numerical order as, in the meantime, the counter might have
been cleared.
ERR 0101
It indicates the error recognition number.
NO EMERGENCY ERROR OR RELAY RESTART ERR
It indicates the message displayed together with the error recognition number. The displayed
message is simplified: for further information, the complete errors list together with the
relevant error explanations and their possible solutions are listed in the manual’s relevant
paragraph.
By means of the keys and , it is possible to check the other errors previously displayed
on the control unit.
ERRLOG 02 SPOT 00175
ERR 0106
STOP LIMIT
LOW CURRENT
ERRLOG 20 SPOT 00138
ERR 0102
THERMOSTAT OR
FLOWSWITCH ERROR
By means of the key
,
it is possible to go back to the previous frames.
By means of the key , one may go back to the main welding frame.
13/92