Instruction manual
ITEM TE550
S.p.A.
By means of the keys and , it is possible to check the other cycles of the analysed
welding.
PRG 001 SPOT 12340
CYC 02 ENERGY 00000J
V+ 00.00 E+ 00000J
V- 00.00 E+ 00000J
PRG 001 SPOT 12340
CYC 10 ENERGY 00000J
V+ 00.00 E+ 00000J
V- 00.00 E+ 00000J
By pressing the key again, it is possible to check the measurements performed by the
control unit when the
position
sensor
is present and powered.
PRG 005 SPOT 01234
THICKNESS 02.486 mm
IDENTATION 0.000 mm
PRG 005
Indicates the programme used to carry out the last weld cycle, ranging from 001 to 250. It is
displayed in WELD and NO WELD mode.
SPOT 01234
Indicates the number of the spot in which the measurement was performed. It is displayed in
WELD and NO WELD mode.
THICKNESS 02.486 mm
Indicates the initial thickness of the material to be welded that the TE550 control unit
measures before current flows. This value is updated in WELD and NO WELD.
IDENTATION 0.000 mm
Indicates the measurement of the electrode indentation into the welded material at the end of
the weld cycle. The value is updated only when in WELD and when the IDENTATION
measurement is enabled in the welding program being used.
By pressing the key again, it is possible to check the measurement carried out by the
control unit when the
pressure sensor
is present and activated.
PRG 005 SPOT 01234
PRESSURE 02.3 bar
PRESS. MIN 01.5 bar
PRESS. MAX 02.5 bar
PRG 005
Indicates the program used to carry the last welding cycle out; it may be a number included
within 001 and 250. It is displayed both in WELD and in NO WELD mode.
SPOT 01234
Indicates the spot number according to which the measurement has been carried out. It is
displayed both in WELD and in NO WELD mode.
12/92