Instruction manual
ITEM TE550
S.p.A.
76/92
CHAPTER 11 -
SELECTING THE WORK PROGRAM THROUGH EXTERNAL
RECALLS
The table below shows which inputs are required to call the work program. The selection is
made through seven inputs, suitably activated in the following combinations.
PROG.
N.
RIC1 RIC2 RIC3 RIC4 RIC5 RIC6 RIC7
1
•
2
•
3
•
•
4
•
5
• •
6
• •
7
•
• •
8
•
9
• •
10
• •
11
•
•
•
12
• •
13
• • •
14
• • •
15
•
•
•
•
16
•
17
• •
18
• •
19
• • •
20
• •
21
• • •
22
• • •
23
• • • •
24
• •
25
• • •
26
• • •
27
• • • •
28
• • •
29
• • • •
30
• • • •
31
• • • • •
32
•
33
• •
34
• •
.....
61
• • • • •
62
• • • • •
63
• • • • • •
64
•
65
•
•
66
• •
.....
123
• • • • • •
124
• • • • •
125
• • • • • •
126
• • • • • •
127
• • • • • • •
• = input active
The recallable programs are 127, when using RIC6 and RIC7 inputs as additional recall
inputs. They are 31 in case RIC6 and RIC7 are not used. The use of RIC6 and RIC7 inputs
can be activated in the
SET UP
Menu (see relevant paragraph).
In order to recall the welding programs correctly, the direct-recall inputs must be
activated before or at the same time as the cycle-start signal.