Instruction manual
ITEM TE550
S.p.A.
CHAPTER 6 - CASCADE WORK MODE
FEATURES MENU
BUTT WELD MODE OFF
SER. SPOT MODE OFF
>CASCADE MODE ON
This function allows the cycle-end signal to be normally closed instead of normally open. As
such, multiple TE550 control units may work in electrical cascade mode.
When two or more control units are connected to one another, the signals used to
synchronize control units and carry out electrical cascade welds are as follows:
- START CYCLE input
- AUX input
- END CYCLE output
All the TE550 control units receive the cycle start signal simultaneously. Connect the END
CYCLE signal to the AUX input of the next control unit. It is advisable to program parameter
CASCADE MODE, of the last control unit, to OFF in order to use the END CYCLE signal with
the normally open contact.
The cascade work mode excludes the possibility of using the control unit in SEAM WELD
MODE
68/92