Instruction manual
ITEM TE550
S.p.A.
The chart below shows the time-study and modalities of the signals used for this operating
mode (referring to the values in the foregoing table).
From the moment the control unit activates the DRESSING ALARM output, it may be reset at
any time by activating the DRESSING CLEAR input as shown in the foregoing chart for
dressings 1, 3 and 4.
In the example, the last DRESSING spot was reached for DRESSING n°2 without clearing the
DRESSING ALARM. In this case the control unit stops and displays the relevant message
(ERROR 116). In this case, first delete the screen from the control unit either using the
ERROR RESET input or using the CLEAR key, and then clear the DRESSING ALARM
output.
The same is applicable to clear the ELECTRODES END LIFE ALARM output.
When the ELECTRODES END LIFE CLEAR
input signal is activated, the control unit resets
the spots counter.
56/92