AutoGRAPH- ST
– Remote Control Command
38
ALARM
Command
ALARM
Name
Alarm mode setting
Supported with firmware
AGST-0.75 and higher
Description
Command is intended to turn on an Alarm mode. This
mode enables data sending via GPRS (to data server),
SMS and Email every 10 minutes. The device will send
data via all channels even if some data transmission
channels are disabled.
Command format:
password ALARM=status;
parameters of the command:
status
– specify following value:
0
– to turn off Alarm mode;
1
– to turn on Alarm mode.
Sample command:
5672 ALARM=1;
Sample reply:
#ALARM=1;
Alarm mode is enabled in the device.