AutoGRAPH- ST
– Remote Control Command
30
SMTPPERIOD
Command
SMTPPERIOD
Name
Email sending period
Supported with firmware
AGST-0.75 and higher
Description
Command provides specifying of the period of sending
Email with current position to preset addresses. This
command is used to specify both the period of Email
sending and the exact time of Email sending. In last
case the device won‟t send the data periodically, but
every day at scheduled time.
Command format:
password SMTPPERIOD=hours,minutes,type;
parameters of the command:
hours,minutes
– a period or exact time of sending Email with current position data.
Minimum value is 10 sec, maximum
– 168 hours (or 1 week).
type
– mode of Email sending:
0
– enables periodical Email sending with the specified period;
1
– enables everyday Email sending at the scheduled time.
Sample command:
5672 SMTPPERIOD=48,30,0;
Sample reply:
#SMTPPERIOD=48,30,0;
The device is set up to send Email with a period of 48 hours 30 min.
Note:
Parameter “type” is available for AutoGRAPH-ST devices with firmware of
version AGST-0.81 and higher. For the previous versions of firmware, use
the following format of the command:
“
SMTPPERIOD=hours,minutes;
”.
These devices support only periodical Email sending.