100BASE-T1 SPY 12 Port
User Manual
9
The power supply for the device is supplied by Pin 18 (12Volt) and Pin 20 (Ground).
Requirements for the 100BASET1_SPY itself: 12 Volt DC up to 1 Ampere (typical
600mA)
Warning
: If a voltage higher than 16 Volt is applied, the device will be damaged!
A wakeup-line may be connected on PIN 5. The wakeup-line should have the same
voltage level as the power supply (12 Volt). A high level on one of these pins wakes up
the ECU from sleep mode and keeps it active.
Alternatively, the “
Prevent sleep
” checkbox in the control panel of the
website can be
enabled.
The CAN, LIN and FlexRay interfaces can be used to communicate with the CAN/CAN-
FD, LIN and FlexRay buses. For LIN and FlexRay buses, no data transmission is
possible.
The Tyco Electronics (TE) Nano Micro Quad Lock System (nanoMQS) is used.
Name
Picture
Part Number
20POS NANOMQS REC HSG CODE A
2141404-1
NANOMQS RECEPTACLE TERMINAL
2-1703930-1
Table 2-1:Parts of black nanoMQS connector
Pin
Function
Pin
Function
1
GND Reference for Trigger
2
Host Trigger Line
3
LIN Bus.
4
FlexRay Channel A BP
5
Wake Line
6
FlexRay Channel A BM
7
CAN D / 5 Minus (Low)
8
CAN E / 1 Plus (High)
9
CAN D / 5 Plus (High)
10
CAN E / 1 Minus (Low)
11
n.c.
12
CAN C / 2 Plus (High)
13
CAN B / 4 Minus (Low)
14
CAN C / 2 Minus (Low)
15
CAN B / 4 Plus (High)
16
n.c.
17
CAN A / 3 Minus (Low)
18
B12 Volt Input
19
CAN A / 3 Plus (High)
20
Battery Ground Input
Table 2-2: Pinning of black MQS connector