6-6
EM18-33017
6. DIAG. TEST OPERATION
Power off
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [PAUSE] key.
Select the ribbon type from those
at the right by pressing the
[FEED] key or [RESTART] key.
Press the [PAUSE] key.
Continued on Section 6.2.3
Head Broken Element Check.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
< 1
D I A G N O S T I C
V 1 . O A
>
R I
B O N
T R A N S M I S S I V E
B
A U
O M A T I C
D I A G N O S T I C
T
C H
C K I N G
&
P R I N T I N G
E
The result of the self test
is printed. After printing,
the initial display will be
shown.
NO RIBBON (No ribbon : Thermal direct)
NO TRANS.
TRANSMISSIVE
(Transmissive ribbon : Thermal transfer)
(Non-transmissive ribbon : Thermal transfer)
The printer is checking or printing
the status
6.2 SELF TEST MODE
6.2.2
Automatic Diagnostic Printing
The data from 1 to 9 on a sample print is printed.
NOTES:
1.
If the automatic diagnosis printing results in an error, the printer will display the
error message and stop printing. The error status can be cleared by the [PAUSE]
key, however, the display will return to the initial display “<1> DIAGNOSTIC
V1.0A”. Printing is not automatically resumed.
2.
Both label and tag paper can be used for printing.