9
DOOR Series -
English
Once the knob has been inserted, fasten the locking screw, insert
the sheath and move the knob to the NOT RELEASED setting.
Only the orange part of the label with the black arrows must be
visible in this position.
Make sure that the system operates correctly by turning the knob
clockwise and keeping the cable taut with the hand.
WARNING: THE KNOB WILL ONLY TURN ABOUT 45-50
DEGREES AND HAS MECHANISMS IN THE FINAL PART,
ALLOWING IT TO REMAIN IN POSITION AFTER BEING
LOCKED.
Apply the supplied label to cover the screw as shown in the figure,
then move the knob back to the NOT RELEASED position.
The cable must now be fastened to the beam, in one of the ways described below:
1_
by using the special slot on the lateral plastic plug (fig. 6A);
fig. A
2_
from underneath the beam, using the 90° bent guide supplied
(fig. 6B). This system is used when there is no room on either
side of the automation.
fig. B
In both cases, when the cable from the solenoid is connected to
the one from the release mechanism, make sure that the release
knob is in the NOT RELEASED position, and that the wire and
sheath from the release mechanism are taut. Route both the
cables (naturally in the opposite direction) into the supplied ter-
minal and tighten them both but without activating the solenoid
(the spring on this latter must only compress a few millimeters).
Now strongly tighten the loose terminal and make sure that both
cables remain taut.
If the cables fail to remain taut, regulate the cable tension using
the relative adjuster in the release mechanism.
Lastly, check to make sure that when the release mechani
-
sm is operated, the solenoid’s core is raised and able to free
the door, and that when the release mechanism is set back
to the NOT RELEASED position, the solenoid’s core is free
to move up and down without impediments or obstructions
of any type.
The release device can be installed directly on the side of the
mechanism by threading the cable through the slot designed for
this purpose.
Install the device using the same procedure as the wall mounted
device.
5
6
7
8
9