17_ DOORSELF MECHANICAL SELECTOR SWITCH
The DOORSELF mechanical selector switch allows you to set the work pro-
gram of the automatic DOOR. To enable its operation, position dip switch 2
of S2 at ON (see TABLE 6).
WARNING:
If you use the DOORSELF mechanical selector switch, the
AUX1 and PEDESTRIAN inputs of the DOOR control unit will lose all their
functions described in paragraph 11.
The DOOR control unit, enabled for operation with the DOORSELF me
-
chanical selector switch, must use the software version of the main
microprocessor MP1 R.4.5 or a higher version.
17.1 – ELECTRICAL CONNECTIONS
TERMINAL 1 = connect to input 13 (INTERNAL RADAR) of the DOOR
control unit;
TERMINAL 2 = connect to input 9 (COMMON) of the DOOR control unit;
TERMINAL 3 = connect to input 12 (AUX1 auxiliary) of the DOOR control
unit;
TERMINAL 4 = connect to input 14 (PEDESTRIAN) of the DOOR control
unit.
17.2 – OPERATING MODE
Rotate the DOORSELF selector knob to select the desired function among
the five available ones:
DOOR ALWAYS OPEN = to keep the door completely open.
If you start opening the door by setting the selector switch to the WINTER OPENING mode, and then immediately turn the knob to
the DOOR ALWAYS OPEN position, the door will stop in the winter opening position.
WINTER OPENING = used to reduce the opening size.
TWO-WAY TRAFFIC = used to open the door via all the control inputs.
OUTBOUND TRAFFIC = used to override inbound traffic detection (EXTERNAL RADAR).
NIGHT LOCK = used to keep the door closed, allowing it to be opened only via the EMERGENCY input.
18_
DOORIM MODULE
The
DOORIM
module is an optional interface card designed for management of
the functions described below.
It has a relay output with dry contact (terminals 1-2), which can be N.O. or N.C.
type (depending on the position of jumper J1) and an OPEN COLLECTOR type
signal output “-”.
The DOORIM
module must be plugged into the LOCK2 connector of the
Door control unit.
• AIR BLADE
Position dip switch 7 of mini-dip S1 at ON.
Use the dry contact on terminals 1 and 2 of the DOORIM
module to command
an air blade, i.e. a device that generates a flow of cold or heated air to sepa-
rate the temperature outside from that inside. The output is active when the
door is moving or open, it is deactivated when the door is closed.
• OPEN DOOR INDICATOR LIGHT
Position dip switch 7 of mini-dip S1 at ON.
Use the dry contact on terminals 1 and 2 of the DOORIM
module to power an
indicator light signalling the door status. The output is active when the door is
moving or open, it is deactivated when the door is closed.
• INTERLOCK FUNCTION
(see paragraph 16)
Connect terminal “-” (OPEN COLLECTOR output) of the DOORIM module to the interlock input (terminal 7) of the second control
unit.
fig. 18
M1
1
2
3
4
SM
0419
44
80
80
fig. 19
J1
J1
NC*
NA**
NC
NA
J1
- 1 2
U
R
1
*
N.C. contact between terminals 1-2.
** N.O. contact between terminals 1-2.