15
DOOR Series -
English
TABLE 4
Emergency input
Photocell 3 input
Start input
Pedestrian opening input
Internal radar input
Interlock input
External radar input
Side sensor input
Photocell 1 input
Auxiliary input
Photocell 2 input
14_ DOORBATT BATTERY OPERATED OPENING DEVICE
Insert the battery charge card in the
J4
connector located on the
motherboard (see side figure).
Be careful not to insert the connector
with the pins misaligned.
Connect the battery, pay attention to the
polarity
(red cable = +, black cable = -)
with respect to the 2 male
fastons on the motherboard.
The DOORBATT card performs the self-testing of the battery charge
level and features a green LED and a red LED. The green LED flashes
while the battery is charging and shows a steady light when the battery
has been charged and is in holding mode. The red LED flashes if the
battery is exhausted or damaged, with or without mains power supply,
whereas it is constantly on when the battery is charged without mains
power. If both LEDs are on it means that the battery is disconnected.
● Check periodically the battery efficiency
● To allow battery reload, batteries must always be connected to the electronic control unit
● The device must be disconnected from power supply when removing the battery
● In case of replacement, use always original batteries (18V, 600mAh).
● The replacement must be carried out by qualified personnel.
● Batteries must be removed before its disposal.
● Batteries contain pollutants, disposal must be performed complying with local rules and regulations.
Battery connector
Battery card connector