![tau DOOR Installation Manual Download Page 14](http://html1.mh-extra.com/html/tau/door/door_installation-manual_821564014.webp)
14
DOOR Series -
English
13_ THE DOOR PROG SELECTOR SWITCH
Connect the digital selector DOORPROG to connector M1 of the control unit “Door” (paragraph 11).
Exhausted battery and power failure signals
Input status signals
Work program selection
Reduced opening selection
Free functions
Locked functions
The key is used to block the selected functions. The required program can be set with the SET button in the FREE FUNCTIONS
mode. The SET button is not activated in the FUNCTIONS BLOCKED mode and the work program will be the last one to have
been selected. The key is also used to access the remote programming menu via selector DOORPROG (see section 15.3).
Exhausted battery and power failure signals:
If the LED shows a steady light, it means that there is no mains power supply but the battery is charged.
If the LED
flashes, it means that there is no mains power supply and the battery is almost exhausted, or it signals also the battery
malfunction status with mains power supply
.
If the LED shows a steady or flashing light, it means that there is no communication between the selector switch and the control unit.
In this case, check the connections between the selector switch and the control unit.
Input status signals:
These LED’s indicate the real-time status of the inputs. Refer to TABLE 4 for the meaning of each LED.
Work program selection:
Press centre button
to switch work program. Refer to TABLE 3 for the meaning of each program.
Reduced opening selection
:
Press the button
to reduce the clear opening (winter opening mode). If the LED on the button is on, it means that the function is
enabled regardless of the selected work program.
To regulate the winter opening distance by potentiometer TM6 from DOORPROG selector switch (see TABLE 7).
Press the button
to obtain a clear opening of approx. 10 cm. (pharmacy opening). If the LED on the button is on, it means that the
function is enabled. To enable the PHARMACY function, set dip 7 of mini-dip S1 in the OFF position (TABEL 5).
TABLE 3
Work programs
Active inputs
Active safety devices
Two-way traffic
Outgoing traffic only
Incoming traffic only
Doors always open
Night lock