![tau DOOR Installation Manual Download Page 21](http://html1.mh-extra.com/html/tau/door/door_installation-manual_821564021.webp)
17
DOOR Series -
English
f)
Once the
UPLOAD
has been completed, the red
BATTERY
LED and the yellow
PHOTOCELL3
LED will light up.
g)
The battery LED signals that the
S1
MINIDIP
is being operated, while the photocell 3 LED signals:
g1)
DIP1
of
S1
in the
ON
position if the LED shows a
steady light
.
g2)
DIP1
of
S1
in the
OFF
position if the LED shows a
flashing light
.
h)
To change the status of the
DIP (ON -OFF)
, press the
WINTER OPENING
button
.
i)
To go to
DIP2
of
S1
, press the
PHARMACY OPENING
button
.
l)
Repeat the last operation above to go to the other
DIPS
of
S1
.
m)
Refer to
TABLES 5 and 6
for the meaning of the
DIPS
.
n)
To operate
MINIDIP S2
, press the
SET
button
, a
POWER
LED will light up.
o)
Repeat the operations described for
MINIDIP S1
to select and change the status of the single
DIPS
.
p)
To go to
POTENTIOMETER
TM1
, press the
SET
button
the
2-WAY
traffic LED
will light up.
q)
When you operate the potentiometers, the inputs LED’s will form a scale to indicate the set value.
r )
To change the value of the selected potentiometer, press:
r1)
the
WINTER OPENING
button
to lower the value
.
r2)
the
PHARMACY OPENING
button
to increase the value
.
s)
To go to
POTENTIOMETER
TM2
, press the
SET
button
.
t)
Repeat the last operation above to go to the other potentiometers.
u)
Refer to
TABLE 7
for the meaning of the potentiometers.
v)
To exit the programming mode and
memorize
the modified values, proceed as follows:
v1) Set the selector switch’s
locking key
in the
locked functions
position
.
v2) Press and hold down the selector switch’s
SET
button
.
v3) Return the
locking key
to the
free functions
position
.
v4) Release the
SET
button
.
v5) The inputs LED’s will light up sequentially
from right to left
to signal the
DOWNLOAD
.
v6) Once the
DOWNLOAD
has been completed, the control unit will emit 2 beeps.
v7) The selector switch will return to normal operation.
z)
To exit the programming mode
without memorizing
the modified values, proceed as follows:
z1) Set the selector switch’s
locking key
in the
locked functions
position
;
z2) Return the
locking key
to the
free functions
position
,
z3) The selector switch will return to normal operation and the control unit will emit 1 beep.
15.4_ RESET OPERATION
To RESET the control unit without disconnecting the mains power source, proceed as follows: access the programming mode with
selector DOORPROG, follow steps A) to E) in section 15.3, then quit the programming mode by following steps Z1) to Z3) of section
15.3.