Tandberg Data
Hardware Interface
___________________________________________________________________________
Tandberg SLR Reference Manual
8-5
8.3.3. SCSI Interface Timing
#
Symbol
Description
Min. (ns)
Max. (ns)
Note
Output and Input Cycles
1
tAAROH
-ACK (in) low to -REQ (out) high
50
2
tAAROL
-ACK (in) high to -REQ (out) low
50
a, b
3
tARAOH
-REQ (in) high to -ACK (out) high
50
4
tARAOL
-REQ (in) low to -ACK (out) low
50
b, d
Output Cycles
5
tARDSO
Data setup to -REQ (out) low
60
5
tAADSO
Data setup to -ACK (out) low
60
6
tARHDO
Data hold from -REQ (in) high
20
c
6
tAAHDO
Data hold from -ACK (in) low
30
c
Input Cycles
7
tAAROH
-ACK (in) low to -REQ (out) high
50
8
tAAROL
-ACK (in) high to -REQ (out) low
50
a, b
9
tARAOH
-REQ (in) high to -ACK (out) high
50
10
tARAOL
-REQ (in) low to -ACK (out) low
50
b, d
11
tARDSI
Data setup to -REQ (in) low
0
11
tAADSI
Data setup to -ACK (in) low
0
12
tARHDI
Data hold from -REQ (in) low
15
12
tAAHDI
Data hold from -ACK (in) low
15
TABLE NOTES:
a) tARDSO specification must also be met (output cycle only)
b) The FIFO is not full (input cycle only)
c) tAADSO specification must also be met (output cycle only)
d) The FIFO is not empty
Table 8.6 SCSI Asynchronous Timing
-REQ (OUT)
-ACK (OUT)
-SDP1-0
-SD15-0
1
3
2
4
5
6
-REQ (IN)
-ACK (IN)
-REQ (OUT)
-ACK (OUT)
-SDP1-0
-SD15-0
7
11
12
-REQ (IN)
-ACK (IN)
8
9
10
OUTPUT
INPUT
Figure 8.1 SCSI Asynchronous Timing Diagrams