3.6.6.1. Data Error Rates
Error Rate Specification - Tandberg SLR7:
Tape
Format
↓
Hard Write
Error Rate
Rewrite
Error Rate
Soft Read
Error Rate
Raw Read
Error Rate
Hard Read
Error Rate
2)
ALRF-2
NOTE 1
< 5 %
< 2 x 10-
6
< 1 x 10-
6
< 10-
16
QIC-4GB
N/A
N/A
< 1 x 10-
7
< 3 x 10-
9
< 10-
15
Error Rate Specification - Tandberg SLR50:
Tape
Format
↓
Hard Write
Error Rate
Rewrite
Error Rate
Soft Read
Error Rate
Raw Read
Error Rate
Hard Read
Error Rate
2)
MLR3 (SLR50)
NOTE 1
< 1.5 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
QIC-5010-DC
NOTE 1
< 1.5 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
SLR6 (SLR24)
NOTE 1
< 1.5 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
QIC-4GB
N/A
N/A
< 1 x 10-
7
< 3 x 10-
9
< 10-
15
QIC-2GB
N/A
N/A
< 1 x 10-
7
< 3 x 10-
9
< 10-
15
Error Rate Specification - Tandberg SLR60 and SLR75:
Tape
Format
↓
Hard Write
Error Rate
Rewrite
Error Rate
Soft Read
Error Rate
Raw Read
Error Rate
Hard Read
Error Rate
2)
ALRF-1
NOTE 1
< 5 %
< 2 x 10-
6
< 1 x 10-
6
< 10-
17
MLR3 (SLR50)
NOTE 1
< 3 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
QIC-5010-DC
N/A
N/A
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
SLR6 (SLR24)
N/A
N/A
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
QIC-4GB
N/A
N/A
< 1 x 10-
7
< 3 x 10-
9
< 10-
15
QIC-2GB
N/A
N/A
< 1 x 10-
7
< 3 x 10-
9
< 10-
15
ALRF-2
N/A
N/A
< 2 x 10-
6
< 1 x 10-
6
< 10-
16
Error Rate Specification - Tandberg SLR100:
Tape
Format
↓
Hard Write
Error Rate
Rewrite
Error Rate
Soft Read
Error Rate
Raw Read
Error Rate
Hard Read
Error Rate
2)
ALRF-1
NOTE 1
< 5 %
< 2 x 10-
6
< 1 x 10-
6
< 10-
17
ALRF-2
N/A
N/A
< 2 x 10-
6
< 1 x 10-
6
< 10-
16
MLR3 (SLR50)
NOTE 1
< 3 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
QIC-5010-DC
N/A
N/A
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
SLR6 (SLR24)
N/A
N/A
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
Error Rate Specification - Tandberg SLR140:
Tape
Format
↓
Hard Write
Error Rate
Rewrite
Error Rate
Soft Read
Error Rate
Raw Read
Error Rate
Hard Read
Error Rate
2)
ALRF-6
NOTE 1
< 5 %
< 2 x 10-
6
< 1 x 10-
6
< 10-
17
ALRF-1
NOTE 1
< 5 %
< 2 x 10-
6
< 1 x 10-
6
< 10-
17
ALRF-2
N/A
N/A
< 2 x 10-
6
< 1 x 10-
6
< 10-
16
MLR3 (SLR50)
NOTE 1
< 3 %
< 1 x 10-
6
< 5 x 10-
7
< 10-
17
NOTES:
1) The Hard Write Error Rate will be a function of factors such as operating environment, head cleaning intervals, tape changing inter-
vals etc.
2) The specified Hard Read Error Rates assume independent errors. The hard read error rate is a calculated value. It is measured
through calculations based on the soft read error rate and the raw read error rate which are both measurable.
3) Please note the important SLR60/75/100/140 recommendation described in Section 5.2.1.