4.2.1. Selecting Drive Number
The factory default drive number setting is Drive 0. If the Drive has to be set up as a different
unit number, the straps have to be connected to ground according to the following table
(Strap connected = CLOSED):
SEL 3
SEL2
SEL1
SEL0
Meaning
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
CLOSED
OPEN
OPEN
OPEN
OPEN
CLOSED
CLOSED
CLOSED
CLOSED
OPEN
OPEN
OPEN
OPEN
CLOSED
CLOSED
CLOSED
CLOSED
OPEN
OPEN
CLOSED
CLOSED
OPEN
OPEN
CLOSED
CLOSED
OPEN
OPEN
CLOSED
CLOSED
OPEN
OPEN
CLOSED
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
OPEN
CLOSED
Select Drive 0
Select Drive 1
Select Drive 2
Select Drive 3
Select Drive 4
Select Drive 5
Select Drive 6
Select Drive 7
Select Drive 8
Select Drive 9
Select Drive 10
Select Drive 11
Select Drive 12
Select Drive 13
Select Drive 14
Select Drive 15
Figure 4.4 The Tandberg SLR32/SLR50 Mainboard (part of)