Troubleshooting and Diagnostics
Error
Messages and Error Codes
AUTOLOADER LTO3 – User Reference Manual Rev. 1.01
TANDBERG DATA
Page 4 9 of 79
9.4.11 Function Errors 90h – 9Fh
Error Code
Description
Recommended Action
90h
Mechanical initialization failure.
The robotic wasn’t able to get into its safe
mechanical init position. Manual
intervention will be necessary.
Reset the unit (menu item
CONFIGURATION/RESET), after
further occurrence contact
Technical support
91h
Scan failure.
Fatal error during cartridge scan, building
up invent ory.
Perform an inventory rescan
(menu item COMMANDS/RE -
INVENTORY)
92h
Preposition failed.
Belt positioning error.
Run Library Verify Test (menu item
DIAGNOSTICS/LOADER
DIAG./LIBRARY VERIFY), after
further occurrence contact
Technical support
93h
Cartridge mount error.
Movement of cartridge into drive failed.
Run Library Verify Test (menu item
DIAGNOSTICS/LOADER
DIAG./LIBRARY VERIFY), after
further occurrence contact
Technical support
94h
Cartridge dismount error.
Failure during cartridge removal and
transport back to the slot.
Run Library Verify Test (menu item
DIAGNOSTICS/LOADER
DIAG./LIBRARY VERIFY), after
further occurrence contact
Technical support
95h
Import error.
Device wasn’t able to finish import of new
cartridge without error.
Run Library Verify Test (menu item
DIAGNOSTICS/LOADER
DIAG./LIBRARY VERIFY), after
further occurrence contact
Technical support
96h
Export error.
Fatal error during cartridge export.
Run Library Verify Test (menu item
DIAGNOSTICS/LOADER
DIAG./LIBRARY VERIFY), after
further occurrence contact
Technical support
97h-9Fh
Reserved