The 4 LEDs (1-4) are updated during power up and reset sequences. Upon power up or software
reset, the autoloader will illuminate all LEDs as soon as power on self-test (POST) allows. This will
help the user to verify if all LEDs are functional.
When mechanical initialization starts, all LEDs will be extinguished and the READY/ACTIVITY LED (1)
will flash at a reasonable rate of approximately 1-second per cycle, 50% duty cycle.
When the mechanical initialization is complete, the READY/ACTIVITY LED (1) will stop flashing and
be constantly illuminated.
If an autoloader failure occurs, the READY/ACTIVITY LED (1) will be turned off and the error LED (4)
will be illuminated. The operation panel will also display an appropriate error code to help identify the
failure.
8.3 Using the Operator Panel and Menu Options
Figure 19
Operator panel
( 1 ) READY/ACTIVITY, Green LED
It is lit any time the unit is powered on and able to function. It should blink whenever there is
autoloader or drive activity.
( 2 ) CLEAN DRIVE, Amber LED
It will be lit when the drive is to be cleaned. The LED will be turned off after the drive is cleaned
successfully.
( 3 ) MEDIA ATTENTION, Amber LED
It will be lit when there has been a failure that indicates that there is a piece of media that is bad,
marginal or invalid. It will be cleared when all invalid cartridges have been exported from the
autoloader.
( 4 ) ERROR, Red LED
It should be lit when there is an unrecoverable autoloader or drive failure. A message is
displayed at the same time on the screen. It will be cleared when the error state is resolved.
( 5 ) CD display, consisting of two lines with 16 characters per line
The screen displays actions and status information, menu items or error messages equivalent to