To adjust finishing of embroidering
108
Chapter 5
7-4.
To change stitching condition in every needle bar (Setting in units of Needle bar)
7-4-1.
Explanation on the screen
[a]
Needle bar No. applied to sewing condition
Perform the following setting for this needle bar.
[b]
Maximum speed
[c]
Number of upper thread breakage detecting times
Setting how many consecutive detections of upper thread breakage are regarded as thread
breakage
0: Not to stop even if upper thread breaks
When idling the machine, set "Upper" and "Under (Unit)" to "0".
1, 2, 3, 4: To stop if upper thread is broken
When selecting "3", the thread breakage will be detected after upper thread breaks three
times continuously.
The relationship between the number of detecting times and sensitivity is shown as follows.
SET
3 Setting in units of Needle bar
F1
Needle No.
Revolution Limit
Thread Detection
ATH
900
rpm
Upper thread
2
0/1/2/3/4
Under (Unit)
4
0/2/4/6/8
Under (Step Ratio)
80
30 100[%]
+3
-8 +8
Return stitches
2
[b]
[c]
[d]
[e]
[f]
[g]
[a]
3 Setting in units of Needle bar
0.6
[mm]
2.0
[h]
SET
F1
Return Stitch Length
0.6
Needle No.
To the next page
Thread trim length
1/2/T0/T1/T2/NO
0.4
[i]
Tie Stitch Length
0.6
[mm]
2.0
1
High
4
Low
2
3
[Sensitivity]
Summary of Contents for TFMX-IIC
Page 2: ...TISM...
Page 14: ...To search from the menu key...
Page 39: ...25 1 2 3 4 5 6 7 8 9 10 11 Chapter 3 Screen 1 Screen display 26 2 Message display 31...
Page 90: ...Embroidery starts 76 Chapter 4...
Page 158: ...Functions that must be remembered 144 Chapter 5...
Page 202: ...Design saved in USB memory 188 Chapter 7...
Page 226: ...Functions concerning optional device 212 Chapter 8...
Page 250: ...236 Inspection Repair Chapter 10...
Page 266: ...Index...
Page 267: ...1st Edition June 2004 47th Edition April 2020...
Page 268: ......