216
Countermeasure when the machine stopped
Chapter 9
2B3 Data exists in an end code.
Correct design data.
2B4 Function code error
2B5 Sequin data error
2B7 Data set is not completed.
Set data.
2BA Memory capacity exceeded
Delete unnecessary design(s) registered in
the memory.
2BB
Available range to perform frame back was
exceeded.
Do not perform frame back any more.
2BC
No design is registered in the memory at all.
Register designs in the memory.
The delete of design in process of embroidery was
attempted.
To perform memory delete of design in
process of embroidery, perform data input of
other data or perform data input of the same
design again.
Data edit was attempted during embroidery.
Do not perform data edit during embroidery.
2BE
Start and End codes are not set as a one pair in
satin conversion, sequin, boring and low speed
code.
Set again so that start and end codes
become as a pair.
2C1
Machine was started during setting of data edit or
needle bar selection.
Start the machine after ending the setting.
2C2 Setting for option is incorrect.
Set correctly.
2C6
The machine was operated during working of
bobbin changer.
Do not operate the machine during working
of bobbin changer.
2C7 Wrong password is input.
After pressing E key, input the correct
password.
2C8 Sleep mode key was pressed during trace.
Press the E key.
2C9
Time was changed during setting of Password
(Time-based Limit).
Press the E key.
2CA The power is not turned "OFF/ON".
Turn "OFF/ON" the power.
2CE Stop by safety device
After removing the obstacle, press E key,
then press the start switch.
2E2
Air pressure of the regulator has become lower than
the rated value.
Check the air compressor. Check the origin
of air supply.
2E3 Power supply failed during operation.
Perform power resume operation after
turning ON the power.
B01 Abnormality occurred in reading/writing.
Copy design to a new USB memory and use
it.
B04 USB memory is not inserted.
Insert.
BC1 Design tried to input is not in design spooler.
Check the condition of design spooler.
BC2 The same file name exists in USB memory.
Change the file name.
BC5 Insufficient remaining capacity of USB memory
Replace with a USB memory with enough
remaining capacity.
No.
Stop Factor
How to restore
Summary of Contents for TFMX-IIC
Page 2: ...TISM...
Page 14: ...To search from the menu key...
Page 39: ...25 1 2 3 4 5 6 7 8 9 10 11 Chapter 3 Screen 1 Screen display 26 2 Message display 31...
Page 90: ...Embroidery starts 76 Chapter 4...
Page 158: ...Functions that must be remembered 144 Chapter 5...
Page 202: ...Design saved in USB memory 188 Chapter 7...
Page 226: ...Functions concerning optional device 212 Chapter 8...
Page 250: ...236 Inspection Repair Chapter 10...
Page 266: ...Index...
Page 267: ...1st Edition June 2004 47th Edition April 2020...
Page 268: ......