86
Replacing Modules
TB9100 Installation and Operation Manual
© Tait Electronics Limited May 2006
7.9
Replacing the Subrack Interconnect Board
There are two types of subrack interconnect board available, as follows:
■
for base stations with PMU
■
for base stations with 12V PA
shows the two types of board, and
explains the settings for the switches on the 12 V PA
interconnect board.
Removal
1.
If you have not already done so, carry out the instructions in
liminary Disassembly” on page 75
, and remove the control panel, as
described in
“Replacing the Control Panel” on page 77
.
2.
Disconnect any system control bus cables.
3.
Remove the M3 nuts and spring washers
b
securing the interconnect
board to the subrack, as shown in
.
4.
Remove the board. If you are changing the type of board, also remove
the insulator
c
.
Refitting
1.
If previously removed, replace the insulator. If you are changing the
type of board, you must fit the matching insulator.
2.
Refit the board and secure with the M3 nuts and spring washers.
3.
If you have fitted a 12V PA interconnect board, set the switches of S1
d
as described in
4.
Reconnect the system control bus cables as shown in
.
Summary of Contents for TB9100
Page 1: ...MBA 00002 05 Issue 5 May 2006 TB9100 base station Installation and Operation Manual...
Page 6: ...6 TB9100 Installation and Operation Manual Tait Electronics Limited May 2006 Glossary 131...
Page 26: ...26 Description TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Page 34: ...34 Maintenance TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Page 60: ...60 Installation TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...
Page 74: ...74 TB9100 Installation and Operation Manual Tait Electronics Limited May 2006...