56
Operator´s manual BIO bale processor B4000
5.6.4 Error/warning codes
The following table gives an explanation on the error codes:
If an error occurs the control panel will activate an alarm signal for a few seconds. The error
code or restriction that caused the alarm signal can then be read in the screen. The error code
in the screen can be cleared at any time by operating the Clear switch. The following screens
are examples that can show up:
The computerised control system
Error
mes-
sage
Symbol Description
Remarks
01
No pulse from net roll during net binding
sequence
02
Net is applied without net binding se-
quence being activated
03
Net knife not under tension
04
No pulse from net actuator
May occur at short circuit in the sensor.
06
No pulse from “prestretcher ring drive”
sensor
Prestretcher ring not turning.
08
Top section of bale chamber not opened
09
Top section down error
Too long time without any signal of top
section having reached lower position
10
Bottom section open / ring up error
Too long time without any signal of bot-
tom section having reached upper posi-
tion
12
Cutter down error
Cutter has not activated Cutter closed
sensor
13
Top section position” sensor not acti-
vated
One of the sensors is faulty
14
Voltage drop
Occurs when voltage drops below the
level set in Dealer menu 4
15
Film break is detected
Occurs if the machine is fitted with film
break sensors, and the film roll is empty
27
Prestretcher ring outside Safe sector
Safe sector sensor not activated
28
Top section not raised
Occurs when a function requiring top
section stay open, is activated while top
section is not completely raised
30
Bottom section not raised/ ring not low-
ered
Occurs when a function requiring bottom
section is raised, is activated while bottom
section is not completely raised
32
Cutter not closed
Occurs when a function requiring film
cutters are close, is activated while cut-
ters are not completely closed
Summary of Contents for BIO+ B4000
Page 2: ...2 Operator s manual BIO bale processor B4000 ...
Page 13: ...13 Fig 2 Fig 1 Fig 3 Fig 4 Fig 6 Fig 5 Fig 7 Fig 8 Safety ...
Page 15: ...15 Fig 10 Fig 9 Fig 11 Fig 12 Fig 13 Safety ...
Page 75: ...75 ...
Page 76: ...76 Operator s manual BIO bale processor B4000 Notes Notes ...
Page 77: ...77 ...