60
Operator´s manual BIO bale processor B4000
5.7.6 ½ speed sensor
If a film break occurs at one of the rollers, the bale can be finished
using the other film roller.
1/2
= ½ speed automatically activated on film break
1/2 F = ½ speed is always activated
—— = Full speed is always activated
5.7.7 Top section opening angle
MID : defines the opening angle of the top section when baling only -
editable.
5.7.8
Calibration of top section
Values for closed and opened top section have to be defined.
Adjustment is to be made first with closed and then with opened bale
chamber. Use the manual hydraulic function to close and open the
bale camber.
Confirm each final position with the
key and then store ith the
key.
5.7.9 Screen information
RPM : 0, no info. 1, show ring RPM in the screen. 2, show filmbreak-
pulses in the screen
ERR : 0, normal display of error messages. 1, the last error message
is shown as a number in the right hand side of the display.
5.7.10 Voltage alarm
Sets the lowest voltage level for releasing the voltage drop alarm.
The computerised control system