9
PLUMBING REQUIREMENTS
This equipment must be installed to comply with the applicable federal, state or local plumbing codes.
WATER TREATMENT IS REQUIRED TO PRESERVE THE FULL MACHINE WARRANTY. Please ensure that the
incoming water complies with the warranty requirements listed on page 8.
Using the provided stainless steel braided hose, connect the pump to the shutoff valve on the filtered cold
water line. Fittings on the hoses and pumps are
3/8”
tube compression. Thread sealant or Teflon tape is
not necessary. Make connections snug, but do not over tighten.
Turn incoming water ON and check for leaks.
Synesso machines require a minimum of 50 PSI (3.5 bar) of line pressure at 30 gal (120 L) per hour to have
the auto
-
fill system for the steam tank functioning properly. Please ensure that the incoming water meets
this requirement or contact Synesso for alternative methods of boosting water pressure.
NOTE: Synesso sells a
“
Euro
-
hose
”
adapter hose and fitting) which converts from a
3/8”
tube fitting to a
pipe fitting, suitable for most non
-
US plumbing. Please refer to the picture below to identify the differ-
ences between the standard and Euro
-
style fittings and hoses.
1/4”
NPT
3/8”
Tube Compression
3/8”
BSP Pipe
Standard Fitting
Standard Hoses
(48”
or
84”)
Euro Hose
Euro Fitting
(Euro Assembly
-
hose +
fitting)
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...