TROUBLESHOOTING
•
Debris caught in the fill valve or valve is worn. Inspect the valve.
•
Debris caught in the inlet flow restrictor. Remove inlet tube and inspect threaded flow restrictor for clog.
•
Level probes (lower and upper) are touching. Angle the probes away from each other.
•
Electrical signal error. Contact Synesso
™
Technical Support for further troubleshooting.
Steam Tank is Overfilling:
•
Water quality is not in spec. The water level probe requires a low level mineral content in order to detect
the water and relay information to the CPU. Do not use deionized water in the machine.
•
Debris caught in the water control valve or worn out valve.
•
Calcium deposits on the fill probe are preventing the probe from detecting the water level.
The Sight Glass Shows Over or Under Filled Steam Tank:
•
Machine is not level. Check to make sure the surface that holds the machine is level. Slightly adjust leg
height to level the machine.
•
Water level is too high; use the hot water spout to drain water from the steam tank. Continue releasing
hot water until the autofill system activates. Once autofill stops, recheck the water level.
•
Debris is stuck in the water control fill valve.
•
Level probes require inspection. Clean or replace probes as needed.
Steam Has Undesirable Smell; Water from Tank is Discolored and/or Has Debris:
•
The tank is contaminated. Drain the tank and refill. If quality of water and steam does not improve, soak-
ing the tank with a cleaning or descaling solution may be necessary along with more clean water rinses.
Please re
-
read best practices regarding steam wand purging before and after steaming (see page 24).
•
Inspect the vacuum breaker. If vacuum breaker is stuck closed, replace.
Steam Valve
Steam Valve Stem Seal Leaks:
•
Replace O
-
rings. Purchase Rebuild Kit
Steam Valve Stem is Engaged; No Steam or Weak Pressure:
•
Inspect steam wand tip. Make sure all holes are cleared.
•
Disassemble valve and inspect for debris.
•
Steam valve shutoff valve is not in the fully ON position
•
Buildup in steam pathway. Inspect tubes and fittings for clog, can be caused by scale buildup in steam
outlet fitting of steam tank.
Hot Water Tap
No Water Flows When the Switch is Pressed:
•
One or more of the following components may have failed: the hot water switch, the solenoid switch, the
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...