To clear the Error Log, press the 4th line button 2 times so that [CLEAR] is flashing. Press an arrow button to
select clear. The 4th line will ask you to confirm clearing the error log as shown below.
Change the flashing [NO] to [YES] to immediately clear the log. Press the 4th line button with [NO] still flash-
ing to exit without clearing the log.
See pages 43
-
50 for information regarding errors and error troubleshooting. .
To cycle to the next display screen, press the down button.
Menu Level 2: Error Log
This is the last screen in the second level of menus.
Pressing the 3rd line button will take you back to the temperature overview screen in the 1st level of men-
us.
Accessing Menu Level 3:
Access to the 3rd level of menus is only available from the Return to Operation Mode screen.
Menu level 3 contains machine configuration settings which do not change over the life of the machine.
Technicians will need to access this level only if some major modification has been preformed, or if the
main electronics board has been replaced.
To access menu level 3, press and hold the home button. Press and release the 4th line button, then re-
lease the home button.
Menu Level 2: Return to Operations
PROGRAMMING
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...