![Synesso MVP Technical Manual Download Page 13](http://html.mh-extra.com/html/synesso/mvp/mvp_technical-manual_1420889013.webp)
13
MODEL SPECIFIC REQUIREMENTS & INSTALLATION
MVP Hydra Vs. MVP:
The MVP Hydra and MVP models differ based on the how many pumps and motors per group head they
have, as well as the functionality that the pump assemblies provide. The MVP Hydra model machine comes
with a pump and motor for each group head, with each pump having a bypass assembly. The MVP has a sin-
gle pump and motor for the entire machine and does not come with a bypass assembly.
In addition, the MVP Hydra has internal plumbing and wiring to accommodate separate and distinct pres-
sures in each brew group. Having individual pumps and motors allows the operator to control brewing pres-
sure at each group head. Each brew group also functions independently without affecting the pressure at
the other groups.
Because of these differences the two models have slightly different installation processes and require-
ments. Please read below for details.
Model Specific Color Coding:
Depending on the MVP Series model and number of groups, color
-
coded zip ties will be present on the wa-
ter lines, electrical cords, and pump/motors.
The colors are as follows:
•
Group 1: Grey
•
Group 2: Purple
•
Group 3: Brown
•
Water inlet for the steam tank: Pink
•
Optional Line Boost System: Red
Wherever these colors are seen, it is critical for proper machine function that they are matched up correctly
(grey to grey, etc.) for both electrical and plumbing systems.
Model Specific Electrical Requirements:
The multiple pump, MVP Hydra machines have a slightly greater amp draw than the single pump, MVP ma-
chines; please note the max amp draws and plan your electrical installation accordingly. See table on page
10.
For the MVP Hydra package, the pump/motor cords should be matched to the appropriate pump/motor by
the color of zip tie. See above for details regarding the different colors.
MVP Pump Assembly
MVP Hydra Pump
Assembly with Bypass
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...