![Synesso MVP Technical Manual Download Page 17](http://html.mh-extra.com/html/synesso/mvp/mvp_technical-manual_1420889017.webp)
17
START UP
Start
-
Up Instructions
1.
Connect the water lines and the drain hose. Turn the water ON. Water will begin to flow into the brew
groups.
2.
Ensure the heating element breaker switch is in the OFF position. Then switch the red electronics On/Off
switch to the ON position. The machine
’
s auto
-
fill feature will activate and the steam tank will begin filling.
3.
The water level sight glass for the steam tank is located on the right side of the machine. As the tank fills,
the water level will rise in the sight glass and will automatically stop when the correct level is reached.
4.
Bleed the group heads of air:
•
Hold each brew group handle left until the corresponding display reads M: shift each group head handle
left momentarily, (see pictures below) allow the group to run until there is a steady flow of water. Shift
each group head right to turn off.
5.
Wait until the steam tank has stopped filling and the level in the sight glass reads at least ½ full. Turn the
heating element breaker to the ON or (1) position. All the heating
elements (brew and steam) are now acti-
vated.
Electronics Switch
ON: up position, light
on
OFF: down position,
light off
Heating Element
Switch
ON: left position (1)
OFF: right position (0)
1
0
Machine Switches
Center Position
—At Rest
Shift Left
-
Start or Advance
Hold Left
-
Changes M to MP to VP
Shift Right
-
Off or Select Brew
Program
Summary of Contents for MVP
Page 12: ...12 INSTALLATION DIMENSIONS ...
Page 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Page 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Page 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Page 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Page 44: ...44 PROGRAMMING Brew System Error Codes ...
Page 45: ...45 PROGRAMMING Brew System Error Codes ...
Page 46: ...46 PROGRAMMING Brew System Error Codes ...
Page 48: ...48 PROGRAMMING Steam System Error Codes ...
Page 49: ...49 PROGRAMMING Steam System Error Codes ...
Page 50: ...50 PROGRAMMING Steam System Error Codes ...
Page 71: ...71 TEMPERATURE OFFSETS ...